D86系列电能表的电磁元件系卧式放置,电磁部公采用分离形式,电压铁芯半封闭插入式,轴承部分采用双宝石结构,计数器为五位和六位数据,为防止反转窃电,可安装双向计数器,计数器传动轴嵌有人造刚玉,可减少齿轮磨擦,保持数据稳定,罩壳分金属(铝)、塑料(ABS)二种,基架系铝全金铸成,经过冷热处理,机械性强

Product DescriptionDD862 type single-phase watt-hour meter, that is, inductance type single-phase AC active energy watt-hour meter, it is used for measuring active energy at single-phase AC power grid of50Hz or 60Hz. It has many features such as original design, reasonable structure, high overload capability, lower power consumption, long service life, good stability, convenient adjustment and maintenance, etc

Main Technical data1The watt-hour meter conforms to all technical requirements stipulated in national standard GB/T 15283 Alternating Current Watt-hour Meters for Active Encrgy (Classes 0 5, 1 and 2), and total technical requirements for single-phase watt-hour meters (class 2)stipulated in international standard IEC 521.

2The watt-hour meter can be designed into two kinds: Direct connection type and the type of connection through multi-purpose current transformer or multi-purpose voltage transformer.

3According to users requirements, the special watt-hour meters can be designed, including the watt-hour meter that has different reference frequency, reference voltage, different current specifications, positive and negative accumulation and not-return function.

4Start: Undcr referance voltage, reference frequency and COS=1, when the load current cant exceed 0.5% of basic current, the rotor of watt-hour meter can start and rotate continuously.

5Creeping: When current circuit of watt-hour meter has no current, and the voltage applied to voltage circuit is 80%~110% of reference value, the rotary disc of watt-hour meter rotates not more than one circle.

6Power consumption: Undcr the reference voltage, reference temperature and reference frequency, the active energyConsumption of watt-hour meter voltage circuit cant exceed 2W.

7Dielectric performance: When the watt-hour meter can withstand impact waveform(standard 1.2/50 uS waveform) and impact voltage of 6KV peak value for 10 times respectively, it wont be damaged. The circuit-to-earth of watt-hour meter can withstand sine waveform of 2KV and 45~65Hz at AC voltage for 1 min.