Electeical Characteristics at 350mA,Ta=25℃
| Color | Part No | Forward Voltage | Units |
| Min | Typ | Max |
| Daylight | | 30 | - | 34 | V |
Notes:1. The forward voltage is measured with an accuracy of ±0.1VColor Temperature or Dominant Wavelength or Peak Wavelength
| Color | Part No | CCT | Units |
| Min | Typ | Max |
| Daylight | | 5500 | -- | 6000 | K |
Notes:1. The CCT is measured with an accuracy of±200K2. The wavelength is measured with an accuracy of±1nm
Absolute Maximum Ratings| Parameter | Symbol | Rating | Unit |
| white | |
| DC Forward Current(mA) | If | 1050 | mA |
| Peak Pulse Current(mA) | If | 1050 | mA |
| Reverse Voltage | VR | 5 | V |
| LED Junction Temperature | Tj | 125 | ℃ |
| Operation Temperature | Topr | -40--100 | ℃ |
| Storage Temperature | Tstg | -40--100 | ℃ |
| Soldening Temperature | Tsol | 260 | ℃ |
| ESD Sensitivity | Vb | 4000 | V |
General Characteristics at700mA3.1 Luminous Flux at 1750mA,Ta=25℃
| color | Part No | CRI | Flux | Units |
| Min | Typ | Max | |
| Daylight | PREW-2AOC | 75 | 2300 | | 2600 | lm |
Notes:1.Luminous flux is measured with an accuracy of±10%
Reliability Information| Stress | Stress Condition | Stress Duration |
| Room Temperature Operation Life ,RTOL | TA=25℃,IF=3000MA | 1500hour |
| High Temperature Operation Life,HTOL | TA=65℃,IF=3000MA | 1500hour |
| Low Temperature Operation Life,LTOL | TA=40℃,IF=3000MA | 1000hour |
| High Temperature/High Humidity OperationLife ,WHTOL | TA=85℃,RH=85%IF=3000MA | 1000hour |
| Temperature Cycles | -40℃/125,30min dwell,5min transfer | 200cycles |