PH-2011

Pentypephmeter

Specifications:

Range:0.00~14.00PH

Resolution:0.01PH

Accuracy:±0.1PH

Battery:4×1.5V(AG-13)

TemperatureCompensation:0℃~50℃

OperatingTemperature:0℃~50℃

Dimensions:151mm×33mm×20mm

Weight:53g

Operation

1.Removetheprotectivecap

2.Firstcleantheelectrodewithdistilledwater,andsuckitwithfilterpaper.

3.TurnonPHby“ON-OFF”switchlocatedonthetopofbatterycase.

4.ImmersethePHmeterelectrodeinsolutionuptotheimmersionlevel.Undernocircumstancesimmerseabovedisplaylevel.

5.Stirgentlyandwaitforthereadingtostabilize.

6.Afteruse,Switchoffit,Usethedistilledwatercleantheelectrodeandreplacetheprotectivecap.

PHcalibration

1.ImmersetheelectrodeinPH6.86(underthetemperatureof25℃)standardbuffersolutionofphosphate,andgentlyshaketheelectrode.

2.Regulatethetrimmerwithascrewdriveruntilthebuffersolutionvaluecorrespondingtothemeasurementtemperatureisobtained.

3.ImmersetheelectrodeinPH4.01orPH9.18thestandardbuffersolutionofborax.

4.Afteraboutoneminute,untilthebuffersolutionvaluecorrespondingtothemeasurementtemperatureisobtained.

Important:

Theinstrument’sPHrangemustberecalibratedwhenever.

Theelectrodehasbeenused(laid)forlongtimefromthelastcalibration.

Theelectrodehasbeenusedinparticularlytaxingconditions.

Theutmostaccuracyisrequired.

Batteryinstall

Ifthedisplayofmeterfades,toreplaceallthebatteries,Pulloutthebatterycaseandreplacethebatteries.Payattentiontothepolarityofbattery.

Warranty:

Theseinstrumentsarewarrantedfromalldefectsinmaterialandmanufacturingforaperiodofoneyearfromthedateofpurchase.ifduringthisperiod,therepairorthereplacementofpartsisrequiredwherethedamageisnotduetonegligenceorerroneousoperationbyuser,pleasereturnthepartstoeitherdealerorouroffices,andtherepairwillbeeffectedfreeofcharge.

PH-2011

笔式酸度计产品规格:范围:0.00?14.00PH分辨率:0.01PH精度:±0.1PH电池:4×1.5V(AG-13)温度补偿:0℃?50℃工作温度:0℃?50℃尺寸:151mm×33mm×20mm重量:53克操作步骤1。取下保护盖2。先用蒸馏水清洗电极,并用滤纸吸干附在电极上的水分。3。接通位于电池仓上的开关。4。将PH计电极插入被测溶液中,直到液体浸到略底于“浸没线”处。5。轻轻搅动,待数值稳定,读取显示值。6。使用完毕,清洗电极,关掉开关,套上保护套。pH校准1。将PH电极浸入PH值为6.86(温度在25℃)的混合磷酸盐标准缓冲溶液中,轻轻摇动电极。2。用小起子调整电位器,直到显示值与标准缓冲溶液在环境温度下的PH值相符。

3。将PH电极浸入在PH4.01的磷苯二甲酸氢钾或PH9.18的硼砂标准缓冲溶液,轻轻摇动电极。

4。显示值与缓冲溶液的PH值相比应在误差允许范围内。

注意事项

在下列情况下,PH计必须重新校准。校准后已使用(或放置)很长时间电极使用特别频繁测量精度要求比较高。电池安装若背光亮度明显下降或显示值模糊,则应更换电池。更换电池时,拉出电池仓更换即可,注意电池的极性保修:本仪器从出厂之日起保修一年,担保由于生产和材料造成的缺陷。若在但保期间,仪器需要维修或更换,且造成损坏的原因,不是使用者的粗心大意或者使用不当,请将仪器及说明书寄给我们的代理或我们公司,我们将予已免费维修。

 